| Type of
receiver: |
Narrowband straight
receiver with automatic gain control, Bandwidth:
approx. 40Hz |
| Type of
antenna: |
Scope of supply includes an
active ferrite antenna AI01 and 5m of RG174
coaxial cable with BNC male connectors. Optional:
AW02 with RG58, other length of cable |
| Status
info: |
Modulation and field
strength visualized by LEDs
Free running state visualized by LED after
switching to free running quartz clock mode |
| Reception
Control: |
Multiple check of received
time telegram
Plausibility control by using two complete time
telegrams |
| Pulse
outputs: |
Pulse per second and pulse
per minute (optocoupler), pulse width: 200
msec |
|
Interface: |
Single serial RS232
interface |
| Data format of
interfaces: |
Baudrate: 600, 1200, 2400,
4800, 9600, 19200 baud
Framing: 7E1, 7E2, 8N1, 8N2
1 active/passive 20mA current loop output
(selectable)
1 active/passive 20mA current loop input
(selectable)
Output string: 32 ASCII characters with date,
time and status information |
| Physical
dimensions: |
57mm x 160mm x 80mm (height
x width x depth) |
| Electrical
connectors: |
25 pin sub D female
connector
BNC female connector
power cord receptacle |
| Power
supply: |
230V/50Hz |
| Current
consumption: |
ca. 20mA |
| Backup battery
type: |
In case of supply voltage
failure the on-board RTC keeps the time based on
XTAL for more than 150 hours (buffer
capacitor)
Optional: lithium backup battery (life time: 10
years) |
| Form
Factor: |
Rolec TBA 084, IP40
protected |
| Ambient
temperature: |
0 ... 50°C / 32 ...
122°F |
|
Humidity: |
Max. 85% |
|
Options: |
Driver software for Windows
XP®, Windows 2000®, Windows NT®,
Novell and UNIX (NTP Freeware) |
| RoHS-Status of the
product: |
This product is fully RoHS
compliant |
| WEEE status of the
product: |
This product is handled as
a B2B category product. In order to secure a WEEE
compliant waste disposal it has to be returned to
the manufacturer. Any transportation expenses for
returning this product (at its end of life) have
to be incurred by the end user, whereas Meinberg
will bear the costs for the waste disposal
itself. |