Maximum cable length for different output signals in time synchronization
TTL signals (TC-DCLS, PPS, PPM, DCF_MARK) via coax cable (RG58)
- Maximum 50m cable length
- Input level and input sensitivity at the receiver must be observed
RS-232 signals (COM) via shielded data cable
- dependant on cable quality
- dependant on the baud rate of the signal (e.g. 15m at 19200 Baud)
RS-485 / RS-422
- maximum 500m cable length
- dependant on the baud rate of the signal
Modulated IRIG signal (TC-AM/IRIG-B)
- maximum 600m cable length
- dependant on signal noise environment
- dependant on the quality of the coax cable
Ethernet (NTP, PTP, IEEE1588)
- maximum 100m cable length with Cat5 and 100Base-T
- more with switches or hubs
- important! for PTP/IEEE1588 all Switches must be PTP aware
Fiber-Optic Multi-Mode 850nm line (GI 50/125µm or GI 62,5/125µm gradient fiber)(TC-DCLS, PPS, PPM, DCF_MARK)
- with end-to-end fiber maximum 2000m fiber length
|