Key Features
- Synchronization of NTP and SNTP
compatible clients
- Web based status and configuration
interface (Demo)
and console based graphical configuration
utility
- Supported networking protocols: IPv4,
IPv6, HTTPS, HTTP, SSH, TELNET, SCP, SFTP, FTP,
SYSLOG, SNMP
- Alert-Notification system of status
change by Email, WinMail, SNMP or an external
connected display
- Full SNMP v1,v2,v3 support with own
SNMP-daemon for status and configuration and SNMP
Trap messages
- USB Port for installing firmware
updates, locking frontpanel menu access and
backup/restore of configuration and log
files
- Antenna connected with up to 300m of
standard coaxial cable RG58
- Two independant RJ-45 ethernet
interfaces 10/100 MBit
Description
The GNU/Linux operating system of the LANTIMEs SBC
(Single Board Computer) has been optimized to ensure
a high level of security and reliability.
A large LC display shows the state of the internal
GPS receiver and the NTP subsystem. Three LEDs
(green/red) indicate the status of the three main
components: Reference Time (GPS), Time
Synchronization Service (NTP) and Network (Link
status). A fourth red LED is labelled ALARM and can
be configured to signal any event that is covered by
the notification handling routines.
The configuration of the system can be done by
using a standard web browser for accessing the
extensive but straightforward html interface.
Alternatively a text based and menu driven setup
utility can be started from the shell prompt after
logging into the unit via Telnet or SSH.
The security-related features of LANTIME time
servers satisfy highest demands. The time
synchronization data can be reliably signed and
secured by symmetric keys (MD5) and the NTP autokey
procedures. This protects the clients against
manipulated time and man-in-the-middle attacks and
allows them to verify that the NTP packets they
received were send by the LANTIME. Additionally the
whole LANTIME configuration can be done by using
encrypted channels (e.g. SSH, HTTPS or SNMPv3). Every
unused/unneeded protocol can be disabled in order to
reduce possible points of attack.
In order to support network management systems the
LANTIME time servers offer an extensive SNMP
interface, which can be accessed by SNMP V1, V2.c and
V3. It allows the monitoring of all relevant system
parameters (including operating system parameters,
network interface statistics, detailed GPS and NTP
status information as well as the complete system
configuration) and can be used to alter the LANTIME
configuration via SNMP set commands, too.
LANTIME time servers are designed to be deployed
in IPv6 networks, the NTP time synchronization as
well as the configuration interfaces (Web-based, SSH
and SNMP) comes with IPv6 support. You can assign
several IPv6 addresses and the system supports
automatic configuration by IPv6 autoconf.
The LANTIME M300 GPS is equipped with a high
precision oscillator "TCXO" (look at oscillator options for
details) as standard. The oscillator determines the
holdover characteristics (e.g. when the GPS signal is
disturbed or jammed). For applications with higher
accuracy requirements there are several oscillator
options available.
Because of its modular system architecture it is
possible to equip a LANTIME M300 time server with a
number of different reference time sources.
Optionally several additional frequency-, serial
string- and pulse outputs are available and by
combining two (even different) time sources and
redundant power supplies, high-availability systems
are no problem.
Characteristics
| Type of
receiver: |
6 channel GPS C/A-code
receiver |
| Type of
antenna: |
Remote powered GPS antenna/converter unit, up
to 300m distance to antenna with RG58 and up to
700m distance with RG213 cable |
|
Display: |
LC-display, 2 x 40
characters, with backlight |
| Control
elements: |
Eight push buttons to set
up basic network parameters and to change
receiver settings |
| Status
info: |
Four bicolor LEDs showing
status of:
- reference time
- time service
- network
- alarm |
| Frequency
outputs: |
10 MHz via female BNC
connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: TCXO),
look at oscillator
options |
| Pulse
outputs: |
Pulse Per Second (PPS), TTL
level, pulse width: 200ms |
| Accuracy of pulse
outputs: |
Depends on oscillator
option:
< ±250ns (TCXO, OCXO LQ)
< ±100ns (OCXO MQ, OCXO HQ, OCXO DHQ)
Note: TCXO only available with M300 |
|
Interface: |
Two independent serial
RS232-interfaces, menu configurable |
| Data format of
interfaces: |
Baudrate: 300, 600, 1200,
2400, 4800, 9600, 19200 Baud data format: 7N2,
7E1, 7E2, 8E1, 8N1, 8N2 Time telegram: Meinberg
Standard-Telegram, SAT, Uni Erlangen (NTP),
SPA, NMEA0183 (RMC), COMPUTIME or capture-telegramm |
| Alarm
output: |
Synchronous state of the
module, relay output (changeover contact) |
| Network
Interface: |
2 x 10/100 MBit with
RJ45 |
| Power
supply: |
85-264VAC (50/60Hz) |
| Power
consumption: |
20W |
| Universal Serial
Bus (USB) Ports: |
1x USB Port in front
panel:
- install firmware upgrades
- backup and restore configuration files
- copy security keys
- lock/unlock front keys
|
| Supported Time
String Formats: |
Meinberg Standard
Timestring, Uni Erlangen Timestring, SYSPLEX
Timer, NMEA, Computime, ABB-SPA, SAT,
Arbiter |
|
Single-Board-Computer: |
i386 compatible 500Mhz CPU,
256 MB RAM |
| Operating System of
the SBC: |
Linux with nano kernel
(incl. PPSkit) |
| Network protocols
OSI Layer 4 (transport layer): |
TCP, UDP |
| Network protocols
OSI Layer 7 (application layer): |
TELNET, FTP, SSH (incl.
SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP |
| Internet Protocol
(IP): |
IP v4, IP v6 |
| Network
Autoconfiguration Support: |
IPv4: Dynamic Host
Configuration Protocol - DHCP (RFC 2131)
IPv6: Autoconfiguration Networking -
AUTOCONF
|
| Network Time
Protocol (NTP): |
NTP v2 (RFC 1119), NTP v3
(RFC 1305), NTP v4 (no RFC)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key
Management |
| Time Protocol
(TIME): |
Time Protocol (RFC
868) |
| Daytime Protocol
(DAYTIME): |
Daytime Protocol (RFC
867) |
| IEC
61850: |
Synchronization of IEC
61850 compliant devices by using SNTP |
| Hypertext Transfer
Protocol (HTTP): |
HTTP/HTTPS (RC 2616) |
| Secure Shell
(SSH): |
SSH v1.3, SSH v1.5, SSH v2
(OpenSSH) |
|
Telnet: |
Telnet (RFC 854-RFC
861) |
| Simple Network
Management Protocol (SNMP): |
SNMPv1 (RFC 1157), SNMPv2c
(RFC 1901-1908), SNMP v3 (RFC 3411-3418) |
| Form
Factor: |
Three different variants
are available, standard version is:
19" module case, height: 44.5mm (1U), width:
483mm (84HP), depth: 350mm (Pic. middle)
optional available:
/TGP: 19" desktop case, height: 157mm (3U),
width: 257mm (42HP), depth: 316mm (Pic. top)
/BGT: 19" module case, height: 132mm (3U), width:
483mm (84HP), depth: 260mm (Pic. bottom) |
| Ambient
temperature: |
0 ... 50°C / 32 ...
122°F |
|
Humidity: |
Max. 85% |
| Scope of
supply: |
Included in delivery is our
GPS
antenna incl. converter unit, 20m GPS antenna
cable (RG58) and product documentation. |
| Technical
Support: |
Meinberg offers free
lifetime technical support via telephone or
e-mail. |
|
Warranty: |
Three-Year Warranty |
| Firmware
Updates: |
Firmware is
field-upgradeable, updates can be installed
directly at the unit or via a remote network
connection.
Software updates are provided free of charge, for
the lifetime of your Meinberg product. |
| RoHS-Status of the
product: |
This product is fully RoHS
compliant |
| WEEE status of the
product: |
This product is handled as
a B2B category product. In order to secure a WEEE
compliant waste disposal it has to be returned to
the manufacturer. Any transportation expenses for
returning this product (at its end of life) have
to be incurred by the end user, whereas Meinberg
will bear the costs for the waste disposal
itself. |
| Additional
Information: |
Additional information
about the Meinberg LANTIME family of NTP time
servers and other LANTIME models can be found on
the LANTIME NTP
Time Server Family Page . |
|