LANTIME M300/GLN
NTP Time Server with integrated GPS/GLONASS satellite receiver


The LANTIME M300/GLN is a time server with a combined GPS/GLONASS  satellite receiver and has been designed to synchronize NTP and SNTP compatible clients (servers, workstations, embedded devices) in IP based networks.  The optional input/output interfaces available for this LANTIME M300 model are accessible via rear panel  connectors, offering a large selection of  time synchronization and reference frequency signals to form a central source of time and frequency synchronization in addition to its network time server function.

GPS/GLONASS satellite clock

The combined GPS/GLONASS satellite receiver clock has been designed to provide extremely precise time. It has been developed for applications where conventional radio clocks cannot  meet the growing requirements for precision and stability. High precision availability for mission critical applications that need to be running 24/7 while being fully independent of the geographical position is the key function of this system. The M300/GLN synchronizes its clock by receiving time information from the satellites of the Russian GLobal Navigation Satellite System (GLONASS) and the U.S. operated Global Positioning System (GPS).


GLONASS has been introduced to provide real-time position and velocity determination, initially for military applications. After a modernization program launched in 2002, the GLONASS general availability for civil users and its restored reliability present the Russian system as a globally accessible alternative to GPS.  GLONASS satellites transmit two types of signals: a Standard Precision (SP) signal and an obfuscated High Precision (HP) signal, which is encrypted and reserved for military applications.
Image Zoom Image Zoom


 
The LANTIME M300/GLN is a time server with a combined GPS/GLONASS satellite receiver and has been designed to synchronize NTP and SNTP compatible clients (servers, workstations, embedded devices) in IP based networks. The optional input/output interfaces available for this LANTIME M300 model are accessible via rear panel connectors, offering a large selection of time synchronization and reference frequency signals to form a central source of time and frequency synchronization in addition to its network time server function.

GPS/GLONASS satellite clock
The combined GPS/GLONASS satellite receiver clock has been designed to provide extremely precise time. It has been developed for applications where conventional radio clocks cannot meet the growing requirements for precision and stability. High precision availability for mission critical applications that need to be running 24/7 while being fully independent of the geographical position is the key function of this system. The M300/GLN synchronizes its clock by receiving time information from the satellites of the Russian GLobal Navigation Satellite System (GLONASS) and the U.S. operated Global Positioning System (GPS).

GLONASS has been introduced to provide real-time position and velocity determination, initially for military applications. After a modernization program launched in 2002, the GLONASS general availability for civil users and its restored reliability present the Russian system as a globally accessible alternative to GPS. GLONASS satellites transmit two types of signals: a Standard Precision (SP) signal and an obfuscated High Precision (HP) signal, which is encrypted and reserved for military applications.



 

Key Features
NTP Time Server with integrated GPS/GLONASS satellite receiver

  • 3 Years Warranty RoHS compliant
  • Synchronization of NTP and SNTP compatible clients
  • Web based status and configuration interface (Demo) and console based graphical configuration utility
  • Supported networking protocols: IPv4, IPv6, HTTPS, HTTP, SSH, TELNET, SCP, SFTP, FTP, SYSLOG, SNMP
  • Alert-Notification system of status change by Email, WinMail, SNMP or an external connected display
  • Full SNMP v1,v2,v3 support with own SNMP-daemon for status and configuration and SNMP Trap messages
  • USB Port for installing firmware updates, locking frontpanel menu access and backup/restore of configuration and log files
  • Two independant RJ-45 ethernet interfaces 10/100 MBit


Description
NTP Time Server with integrated GPS/GLONASS satellite receiver


The GNU/Linux operating system of the LANTIME has been optimized to ensure a high level of security and reliability.

A large LC display shows the state of the internal GPS/GLONASS receiver and the NTP subsystem. Three LEDs (green/red) indicate the status of the three main components: Reference Time (GPS only, GPS+GLONASS, GLONASS only), Time Synchronization Service (NTP) and Network (Link status). A fourth red LED is labeled ALARM and can be configured to signal any event that is covered by the notification handling routines.

The configuration of the system can be done by using a standard web browser for accessing the extensive but straightforward web based interface. Alternatively a text based and menu driven setup utility can be started from the shell prompt after logging into the unit via serial console, Telnet or SSH.

The security-related features of LANTIME time servers satisfy highest demands. The time synchronization data can be reliably signed and secured by symmetric keys (MD5) and the NTP autokey procedures. This protects the clients against manipulated time and man-in-the-middle attacks and allows them to verify that the NTP packets they received were send by the LANTIME. Additionally the whole LANTIME configuration can be done by using encrypted channels (e.g. SSH, HTTPS or SNMPv3). Every unused/unneeded protocol can be disabled in order to reduce possible points of attack.

In order to support network management systems the LANTIME time servers offer an extensive SNMP interface, which can be accessed by SNMP V1, V2.c and V3. It allows the monitoring of all relevant system parameters (including operating system parameters, network interface statistics, detailed GPS and NTP status information as well as the complete system configuration) and can be used to alter the LANTIME configuration via SNMP set commands, too.

LANTIME time servers are designed to be deployed in IPv6 networks, the NTP time synchronization as well as the configuration interfaces (Web-based, SSH and SNMP) comes with IPv6 support. You can assign several IPv6 addresses and the system supports automatic configuration by IPv6 autoconf.

The LANTIME M300/GLN is equipped with a high precision oscillator "TCXO" (look at oscillator options for details) as standard. The oscillator determines the holdover characteristics (e.g. when the satellite signals are disturbed or jammed). Several oscillator options can be ordered for applications with higher accuracy needs or more demanding holdover requirement .

A standard coaxial cable with 50 ohm impedance can be used to connect the antenna to the receiver. The maximum length of cable between antenna and receiver depends on the attenuation factor of the used coaxial cable.

Because of its modular system architecture it is possible to equip a LANTIME M300 time server with a number of different reference time sources. Optionally several additional frequency-, serial string- and pulse outputs are available and by combining two (even different) time sources and redundant power supplies, high-availability systems are no problem.



Back to Top


Characteristics
NTP Time Server with integrated GPS/GLONASS satellite receiver


Type of receiver: Combined GLONASS/GPS receiver
  • Number of channels: 24
  • Frequency band: L1
  • Standard Precision (GLONASS)
  • Codes: C/A code (GPS)
Type of antenna: 40 dB GPS L1/GLONASS L1
Antenna with Integrated Lightning Protection
  • Frequency Band: 1575.42 ± 10 MHz / 1602-1615 MHz
  • Antenna Gain: ≥ 3.5 dBic / ≥ 3 dBic
  • Nominal Impedance: 50 ohms
Datasheet GLONASS/GPS Antenna
Display: LC-display, 2 x 40 characters, with backlight
Control elements: Eight push buttons to set up basic network parameters and to change receiver settings
Status info: Four bicolor LEDs showing status of:
- reference time
- time service
- network
- alarm
Frequency outputs: 10 MHz via female BNC connector, TTL into 50 Ohm
Accuracy depends on oscillator (standard: TCXO), look at oscillator options
Pulse outputs: Pulse Per Second (PPS), TTL level, pulse width: 200ms
Accuracy of pulse outputs: Depends on oscillator option:
< ±250ns (TCXO, OCXO LQ)
< ±100ns (OCXO MQ, OCXO HQ, OCXO DHQ)
Note: TCXO only available with M300
Interface: Two independent serial RS232-interfaces, menu configurable
Data format of interfaces: Baudrate: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud
Data format: 7N2, 7E2, 8E1, 8N1, 8O1
Time telegram: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), NMEA (RMC, GGA), SPA, COMPUTIME, SYSPLEX, Meinberg GPS Telegram, !Capture-Telegram!
Alarm output: Synchronous state of the module, relay output (changeover contact)
Network Interface: 2 x 10/100 MBit with RJ45
Power supply: Standard: 100-240 VAC
available DC variants: 100-240 VDC, 12VDC, 24VDC and 48VDC
Power consumption: 20W
Universal Serial Bus (USB) Ports: 1x USB Port in front panel:
- install firmware upgrades
- backup and restore configuration files
- copy security keys
- lock/unlock front keys
Supported Time String Formats: Meinberg Standard Timestring, Uni Erlangen Timestring, SYSPLEX Timer, NMEA, Computime, ABB-SPA, SAT, Arbiter
Single-Board-Computer: i386 compatible 500Mhz CPU, 128 MB RAM
Operating System of the SBC: Linux with nano kernel (incl. PPSkit)
Network protocols OSI Layer 4 (transport layer): TCP, UDP
Network protocols OSI Layer 7 (application layer): TELNET, FTP, SSH (incl. SFTP, SCP), HTTP, HTTPS, SYSLOG, SNMP
Internet Protocol (IP): IP v4, IP v6
Network Autoconfiguration Support: IPv4: Dynamic Host Configuration Protocol - DHCP (RFC 2131)
IPv6: Autoconfiguration Networking - AUTOCONF
Network Time Protocol (NTP): NTP v2 (RFC 1119), NTP v3 (RFC 1305), NTP v4 (no RFC)
SNTP v3 (RFC 1769), SNTP v4 (RFC 2030)
MD5 Authentication and Autokey Key Management
Time Protocol (TIME): Time Protocol (RFC 868)
Daytime Protocol (DAYTIME): Daytime Protocol (RFC 867)
IEC 61850: Synchronization of IEC 61850 compliant devices by using SNTP
Hypertext Transfer Protocol (HTTP): HTTP/HTTPS (RC 2616)
Secure Shell (SSH): SSH v1.3, SSH v1.5, SSH v2 (OpenSSH)
Telnet: Telnet (RFC 854-RFC 861)
Simple Network Management Protocol (SNMP): SNMPv1 (RFC 1157), SNMPv2c (RFC 1901-1908), SNMP v3 (RFC 3411-3418)
Form Factor: 19 inch multipac metal case 1U/84HE - see Physical Dimension LANTIME Time Servers.
Ambient temperature: 0 ... 50°C / 32 ... 122°F
Humidity: Max. 85%
Scope of supply: Each LANTIME M300/GLN will be delivered with a GLONASS / GPS antenna unit mounted in a waterproof plastic case, mounting kit and 20 m (65.6 feet) of low loss antenna cable, and mains connection cable with US-or Europeen power supply plug.
Technical Support: Meinberg offers free lifetime technical support via telephone or e-mail.
Warranty: Three-Year Warranty
Firmware Updates: Firmware is field-upgradeable, updates can be installed directly at the unit or via a remote network connection.
Software updates are provided free of charge, for the lifetime of your Meinberg product.
RoHS-Status of the product: This product is fully RoHS compliant
WEEE status of the product: This product is handled as a B2B category product. In order to secure a WEEE compliant waste disposal it has to be returned to the manufacturer. Any transportation expenses for returning this product (at its end of life) have to be incurred by the end user, whereas Meinberg will bear the costs for the waste disposal itself.
Additional Information: Additional information about the Meinberg LANTIME family of NTP time servers and other LANTIME models can be found on the LANTIME NTP Time Server Family Page .

Back to Top


Downloads
NTP Time Server with integrated GPS/GLONASS satellite receiver

 

More Images

PDF Documents Please note that only the most recent manual version is available for download. This manual therefore may not be suitable for all product versions.

Software Downloads

  • For drivers, SDKs, tools and utilities, please check our Download area
 




spacer
 Home  | Products  | Top  ]
spacer
Meinberg Funkuhren GmbH & Co. KG
Lange Wand 9
D - 31812 Bad Pyrmont
Contact
Phone: +49 (0) 52 81 / 93 09 - 0
Facsimile: +49 (0) 52 81 / 93 09 - 30
Legal Notice and Privacy Policy | Sitemap
Homepage: http://www.meinberg.de
E-Mail: info@meinberg.de
GPS/GLONASS NTP Time Server M300/GLN