Key Features
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type of receiver: | 6 channel GPS C/A-code receiver |
| Type of antenna: | Remote powered GPS antenna/converter unit, up to 300m distance to antenna with RG58 and up to 700m distance with RG213 cable |
| Display: | LC-display, 2 x 40 characters, with backlight |
| Control elements: | Configuration occurs by using the enclosed monitoring software, connected to the system via the serial interface COM0 in the front panel. ../LCD/.. only Configuration occurs via the 2x40 character front panel LC display or by using a monitoring software, connected to the system via the serial interface COM0 in the rear panel. |
| Status info: | Fail-LED shows that the internal timing has not been synchronized or that a system error occurred Lock-LED shows that the calculation of the position has been achieved after reset |
| Synchronization time: | Max. 1 minute in normal operation mode, approx. 12 minutes after a cold start (discharged buffer battery) |
| Interface: | Two independent serial RS232-interfaces, menu configurable |
| Data format of interfaces: | Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200 Baud Data format: 7N2, 7E1, 7E2, 8E1, 8N1, 8N2 Time telegram: Meinberg Standard-Telegram , SAT, Uni Erlangen (NTP), SPA, Sysplex, RACAL, NMEA0183 (RMC,GGA,ZDA), Meinberg GPS, COMPUTIME, ION oder Capture-Telegramm |
| Physical dimensions: | 485mm x 45mm x 305mm |
| Time-Trigger inputs: | Resolution: 100 nsec, triggered by falling TTL slope Time of trigger event readable via RS232-interface |
| Antenna connector: | type-N connector |
| Backup battery type: | When main power supply fails, hardware clock runs free on quartz basis, almanac data is stored in RAM Life time of lithium battery min. 10 years |
| Supported Time String Formats: | Meinberg Standard Timestring, Uni Erlangen Timestring, SYSPLEX Timer, NMEA, Computime, ABB-SPA, SAT, Arbiter |
| Firmware: | Flash-EPROM, bootstrap loader |
| Power Supply Unit: | Standard PSU: 85 ... 264VAC, 47 ... 63Hz Several other power supply units (even for DC power supply) are available upon request. |
| Form Factor: | 19'' aluminium case (1U) Schroff Multipac |
| Protection: | IP20 |
| Ambient temperature: | 0 ... 50°C / 32 ... 122°F |
| Humidity: | Max. 85% |
| Scope of supply: | Included in delivery is our GPS antenna incl. converter unit, 20m GPS antenna cable (RG58) and product documentation. |
| Warranty: | Two-Year Warranty |
Downloads
|
||
|