| Type of
receiver: |
6 channel GPS C/A-code
receiver |
| Type of
antenna: |
Remote powered GPS antenna/converter unit, up
to 300m distance to antenna with RG58 and up to
700m distance with RG213 cable |
| Cable
type: |
Coaxial cable RG58 indoor
or outdoor usage (SMB-, N-Norm-connector) |
| Status
info: |
Fail-LED shows that the
internal timing has not been synchronized or that
a system error occurred
Lock-LED shows that the calculation of the
position has been achieved after reset |
| Synchronization
time: |
Max. 1 minute in normal
operation mode, approx. 12 minutes after a cold
start (discharged buffer battery) |
| Frequency
outputs: |
10 MHz, 1 MHz, 100 kHz (TTL
level)
Accuracy: ±5·10E-9 (timebase TCXO),
GPS-synchronous for more than 20 minutes
Different oscillators available, look at oscillator options |
| Pulse
outputs: |
Pulse per second (PPS) and
pulse per minute (PPM). TTL level, pulse width:
200msec |
| Accuracy of pulse
outputs: |
Dependant on oscillator
option:
< ±250nsec (TCXO, OCXO LQ)
< ±100nsec (OCXO MQ, OCXO HQ, OCXO-DHQ,
Rubidium) |
|
Interface: |
Two independent serial
RS232-interfaces, menu configurable |
| Data format of
interfaces: |
Baudrate: 300, 600, 1200,
2400, 4800, 9600, 19200 Baud data format: 7N2,
7E1, 7E2, 8E1, 8N1, 8N2 Time telegram: Meinberg
Standard-Telegram, SAT, Uni Erlangen (NTP),
SPA, NMEA0183 (RMC), COMPUTIME or capture-telegramm |
| DCF77
emulation: |
DCF77-emulation,
TTL-level |
| Switch
outputs: |
Optional:
3 TTL outputs can configured independently for
the following modes:
- free programmable cyclic or fixed impulses
- timer mode; three 'ON'- and three 'OFF'-states
can be setup per day
The switch states can be inverted for all three
outputs, the impulse lengths are configurable in
10msec steps in a range from 10msec to 10sec.
The impulse output can be configured for all
channels together to 'always' or 'ifsync'. |
| Generated time
codes: |
Optional:
IRIG B002, B122, B003, B123, B006, B126, B007,
B127, IEEE1344 or AFNOR:
- AM-sinewave signal: 3Vpp (MARK), 1Vpp (SPACE)
into 50 ohm
- TTL-level |
| Time-Trigger
inputs: |
Resolution: 100 nsec,
triggered by falling TTL slope
Time of trigger event readable via
RS232-interface |
| Alarm
output: |
Synchronous state of the
module, TTL high level if synchronous |
| Dimensions of the
front panel: |
8HP/3U (40mm x 128mm) |
| Electrical
connectors: |
64 pin rear VG edge
connector DIN 41612 |
| Antenna
connector: |
SMB-Subminiature-coaxial-connector |
| Power
supply: |
+5V DC |
| Current
consumption: |
+5V 1.1 A to 1.4 A
(depending on oscillator type)
|
| Backup battery
type: |
When main power supply
fails, hardware clock runs free on quartz basis,
almanac data is stored in RAM
Life time of lithium battery min. 10 years |
|
Firmware: |
Flash-EPROM, bootstrap
loader |
| Board
type: |
Eurocard |
| Ambient
temperature: |
0 ... 50°C / 32 ...
122°F |
|
Humidity: |
Max. 85% |
|
Options: |
Synthesizer 1/8 Hz up to 10
MHz (TTL level, sine wave 1.5Veff, open
drain)
Optional up to 4 serial interfaces, 3
programmable TTL outputs and timecode generator
(IRIG-B, AFNOR) |
| RoHS-Status of the
product: |
This product is fully RoHS
compliant |
| WEEE status of the
product: |
This product is handled as
a B2B category product. In order to secure a WEEE
compliant waste disposal it has to be returned to
the manufacturer. Any transportation expenses for
returning this product (at its end of life) have
to be incurred by the end user, whereas Meinberg
will bear the costs for the waste disposal
itself. |